
APPENDIXG. ALARM LIST
B–63084EN/02
720
Number ContentsMessage
055 MISSING MOVE VALUE IN CHF/CNR In chamfering or corner R block, the move distance is less than chamfer
or corner R amount.
056 NO END POINT & ANGLE IN
CHF/CNR
Neither the end point nor angle is specified in the command for the block
next to that for which only the angle is specified (A). In the chamfering
common, I(K) is commanded for the X(Z) axis.
057 NO SOLUTION OF BLOCK END Block end point is not calculated correctly in direct dimension drawing
programming.
058 END POINT NOT FOUND Block end point is not found in direct dimension drawing programming.
059 PROGRAM NUMBER NOT FOUND In an external program number search or external workpiece number
search, a specified program number was not found. Otherwise, a pro-
gram specified for searching is being edited in background processing.
Check the program number and external signal. Or discontinue the
background editing.
060 SEQUENCE NUMBER NOT FOUND Commanded sequence number was not found in the sequence number
search. Check the sequence number.
061 ADDRESS P/Q NOT FOUND IN
G70–G73
Address P or Q is not specified in G70, G71, G72, or G73 command.
Modify the program.
062 ILLEGAL COMMAND IN G71–G76 1 The depth of cut in G71 or G72 is zero or negative value.
2 The repetitive count in G73 is zero or negative value.
3 The negative value is specified to ∆i or ∆k is zero in G74 or G75.
4 A value other than zero is specified to address U or W, though ∆i or
∆k is zero in G74 or G75.
5 A negative value is specified to ∆d, though the relief direction in G74
or G75 is determined.
6 Zero or a negative value is specified to the height of thread or depth
of cut of first time in G76.
7 The specified minimum depth of cut in G76 is greater than the height
of thread.
8 An unusable angle of tool tip is specified in G76.
Modify the program.
063 SEQUENCE NUMBER NOT FOUND The sequence number specified by address P in G70, G71, G72, or G73
command cannot be searched. Modify the program.
064 SHAPE PROGRAM NOT
MONOTONOUSLY
A target shape which is not monotonous increase or decrease was spe-
cified in a repetitive canned cycle (G71 or G72).
065 ILLEGAL COMMAND IN G71–G73 1 G00 or G01 is not commanded at the block with the sequence num-
ber which is specified by address P in G71, G72, or G73 command.
2 Address Z(W) or X(U) was commanded in the block with a sequence
number which is specified by address P in G71 or G72, respectively.
Modify the program.
066 IMPROPER G–CODE IN G71–G73 An unallowable G code was commanded between two blocks specified
by address P in G71, G72, or G73. Modify the program.
067 CAN NOT OPERATE IN MDI MODE G70, G71, G72, or G73 command with address P and Q was specified.
Modify the program.
069 FORMAT ERROR IN G70–G73 The final move command in the blocks specified by P and Q of G70,
G71, G72, or G73 ended with chamfering or corner R.
070 NO PROGRAM SPACE IN MEMORY The memory area is insufficient.
Delete any unnecessary programs, then retry.
071 DATA NOT FOUND The address to be searched was not found. Or the program with speci-
fied program number was not found in program number search.
Check the data.