B–62075E/04
4. INTERFACE BETWEEN NC AND PMC
250
(1)Control data table
PMC TABLE CONTROL DATA
NO. ADDRESS PARAMETER NO.OF DATA OFFSET SPECIAL TABLE NO.0
000 D0000 3
001 D0002 00000010 20 0 31520 2150
002 D0010 00001000 10 0 0 20000
003 D0018 00000011 10 0 0 20000
Special display data
Offset data
Number of data items
Table parameters
Table group 1
Table group 2
Table group 3
Data corre-
sponding to
number 0
within the
table
Number of table groups used
a) Parameter format
#7 #6 #5 #4 #3 #2 #1 #0
#7 1 : The data table is used for teaching data.
0 : The data table is not used for teaching data.
#6 1 : The contents of the data table cannot be modified from the MDI.
0 : The contents of the data table can be modified from the MDI.
#3 1 : The data length for the data table is 4 bytes.
0 : The data length for the data table is 1 or 2 bytes.
#2 1 : When the contents of the data table are modified from the MDI, the
same data cannot be entered.
0 : When the contents of the data table are modified from the MDI, the
same data can be entered.
#1 1 : The data length for the data table is 2 bytes.
0 : The data length for the data table is 1 byte.
#0 1 : The data format for the data table is BCD.
0 : The data format for the data table is binary.
Point
The correspondence between the data length
and the settings of bits 3 and 1 is as follows:
#3 #1 Data length
1 1
4 bytes
1 0
0 1 2 bytes
0 0 1 byte
D PMC–NA