B–62075E/04
1. OPERATION OF MDI PANEL
16
Select “1.ALARM” from the help initial menu to display alarm help
information (alarm selection/alarm details).
ALARM SELECTION
:FOREGROUND PROGRAM/SETTING ALM.
BG :BACKGROUND PROGRAM/SETTING ALM.
SR :SERIOUS PROGRAM/SETTING ALARM
OH :OVER HEAT ALARM
SB :SUB CPU ALARM
SW :PARAMETER ENABLE SWITCH ON ALM.
OT :OVERTRAVEL ALARM
1.ALARM
PC :PMC ALARM
SV :SERVO ALARM
IO :I/O ALARM
PW :POWER OFF PARAMETER SET ALARM
(SELECT BY CURSOR & INPUT NUMBER)
PS
Fig. 1.4.2 (b) Sample alarm selection display (14–inch CRT)
ALARM NO. :PS010
DIVISION :GENERAL
AN ILLEGAL G CODE WAS SPECIFIED IN
A NC SENTENCE. THIS ALARM ALSO
OCCURS BY A OPTION ORGANIZATION,
NC SITUATION OR MODE SELECTION,
EVEN IF A G CODE IS PROPER.
1.ALARM
(PUSH INPUT KEY TO RETURN SELECT)
Fig. 1.4.2 (c) Sample detailed alarm display (14–inch CRT)
D Alarm help