B–62075E/04
1. OPERATION OF MDI PANEL
30
(1)Press the [SERVICE] soft key or
SERVICE
key.
(2)Press the [WAVE DIAGNS] soft key. Then, the WAVE DIAGNOSIS
(GRAPH) screen is displayed.
STOP
MEM *** STOP **** *** *** 03:14:18 LSK
WAVE DIAGNOSIS(GRAPH)000000000000111 NNN000000000000333
WAVE
1.X
2.Y
0 500 1000 1500 TIME(MS)
00
SHIFT CHAPT
ER
PARAME-
TER
PUNCHREADERASETRACE
While the WAVE DIAGNOSIS (GRAPH) screen is displayed, press the
[PARAMETER] soft key. Then, the WAVE DIAGNOSIS
(PARAMETER) screen is displayed.
MEM *** STOP **** *** *** 03:14:18 LSK
CHAPTE
R
WAVE DIAGNOSIS(PARAMETER) 000000000000111 NNN000000000000333
CONDITION = 0 DI/DO = X001.1
TRIGGER = X010.1 X001.2
DELAY TIME = 1000 X001.3
X001.4
TIME RANGE = 0
(25,50,100,200,400,800MS)
ZERO SIFT = 0
(WAVE 1) (WAVE 2)
DATA KIND = 0 DATA KIND = 1
DATA RANGE = 1 DATA RANGE = 2
DATA COLOR = 1000 DATA COLOR = 1000
INPUT SET
END
WAVE COLOR = 1 WAVE COLOR = 2
(1)One–shot type waveform diagnosis
The collection of data is started according to a set start condition, and
data changes are displayed graphically.
(a) CONDITION
Enter one of the following settings in the CONDITION field on the
WAVE DIAGNOSIS (PARAMETER) screen.
1.7
WAVEFORM
DIAGNOSIS
FUNCTION
1.7.1
Display of Wave
Diagnosis (Graph)
Screen
1.7.2
Setting the Waveform
Diagnosis Parameters