A-79364E
Title
Draw
No.
Ed. Date Design Description
Date Jan.07.’04 Design. Apprv.
4/13
Page
FANUC Series 30i-MODEL A
Linear scale with distance-coded
reference marks
serial
- Procedure for reference position establishment
through automatic operation
If an automatic reference position return (G28) is specified before a
reference position is not established, steps (3) to (4) above are performed
automatically.
After the reference position is established, the automatic reference position
return is performed by setting of parameter RFS No.1818#0.
- Stopping the operation for establishing a reference
position
The operation for establishing a reference position is stopped if any of
the following operations is performed in steps (3) to (4), described above.
- Reset
- Setting the feed axis direction selection signal (+J1, -J1, +J2, -J2, etc.) to
0
- Setting the Servo off signals (SVF1, SVF2, etc.) to 1
If any of the following operations is performed during the operation of
automatic reference position return (G28) before a reference position is not
established, the operation for establishing a reference position stops:
- Reset
- Performing feed hold during movement from an intermediate position
- Setting the Servo off signals (SVF1, SVF2, etc.) to 1
If the operation for establishing a reference position is stopped by an
operation other than a reset, the operation for establishing a reference
position must be reset and resumed.
- Establishing a reference position and moving to the
reference position
By following operation, establishing a reference position and moving to the
reference position is performed.
Moving through manual
operation in REF mode
Moving through automatic operation by
automatic reference position return (G28)
The reference
position is not
established.
Establishing the reference
position
Firstly, moving to the intermediate position,
and establishing the reference position.
Secondly, whether moving to the reference
position or not is performed by setting
parameter RFS No.1818#0.
The reference
position is
established.
Moving to the reference
position
Whether moving to the intermediate
position and the reference position or not is
performed by setting parameter RF2
No.1818#1.