A-79364E
Title
Draw
No.
Ed. Date Design Description
Date Jan.07.’04 Design. Apprv.
6/13
Page
FANUC Series 30i-MODEL A
Linear scale with distance-coded
reference marks
serial
- angular axis control
In case of using the angular axis control, please confirm the following
items.
- It is necessary to use the linear scale with distance-coded reference
marks (serial) for both the perpendicular axis and the angular axis.
If not, the alarm DS0019 occurs when reference position establishment
is commanded.
- When the reference point establishment of angular and perpendicular
axes are tried, please set parameter 8200#2(AZR) to '0' and input signal
G063#5(NOZAGC) to '0'.
If not, the alarm DS0019 occurs when reference position establishment
is commanded.
- When the reference point of the perpendicular axis is established, it is
necessary to establish the reference point of the angular axis previously.
When the reference point of the angular axis is not previously
established, the alarm DS0020 occurs.
- On angular axis control, if you use automatic setting of parameter
No.1883,1884 on reference point establishment (parameter DATx
No.1819#2=1), please establish reference point of perpendicular axis
after reference point establishment and return of angular axis.
Caution
(1) When the Linear scale with distance-coded reference marks (serial) is
used, please set parameter SDCx No.1818#3 to 1.
(2) And distance coded rotary encoder (serial type) is not available.
(3) On the Linear scale with distance-coded reference marks (serial), the
axis does not stop until three reference marks are detected. If this
procedure is started at the position near the scale end, CNC can not
detect three reference marks and the axis does not stop until over travel
alarm occurs. Please care to start at the position that has enough
distance from scale end.
And if establishment of reference position is failed, the establishment is
retried. Then axis does not stop until still more three reference marks
are detected. So please set the maximum move amount (detection unit :
parameter No.14010) not to reach the scale end.
Scale end
Reference marks
Start point (Bad)
Start point (Good)