FANUC Series 30i-MODEL A
Distance coded linear scale interface
#7 #6 #5 #4 #3 #2 #1 #0
1819 DATx
[Input type] Parameter input
[Data type]
Bit axis
# 2 DATx When a manual reference point return is executed, an automatic setting of
parameter No.1883,1884 is
0 : Not executed.
1 : Executed.
The procedure of the automatic setting are following :
(1) Set a correct value to parameter No.1815,1821,1882.
(2) Positioning the axis to reference position by mechanical measurement by
manual operation.
(3) Set parameter No.1819#2 to '1'.
(4) Execute manual reference point return.
When the manual reference point return is finished, parameter
No.1883,1884 are set and No.1819#2 is turn to '0'.
1821 Reference counter size for each axis
Note
When this parameter is set, the power must be turned off
before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
Set the interval of reference mark 1 of distance coded linear scale.
1882 Interval of reference mark 2
Note
When this parameter is set, the power must be turned off
before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
Set the interval of reference mark 2 of distance coded linear scale.