A-79253E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
17/18
Page
FANUC Series 30i-MODEL A
Distance coded linear scale interface
Alarm and message
Number Message Description
PS5220 REFERENCE POINT ADJUSTMENT
MODE
In case of distance coded linear scale I/F, the reference
point auto setting parameter (No.1819#2) is set to "1".
Move the machine to reference position by manual
operation and execute manual reference return.
DS0020 REFERENCE RETURN INCOMPLETE An attempt was made to perform an automatic return to
the reference position on the perpendicular axis before
the completion of a return to the reference position on
the angular axis.
However, this attempt failed because a manual return to
the reference position during angular axis control or an
automatic return to the reference position after power-up
was not commanded. First, return to the reference
position on the angular axis, then return to the reference
position on the perpendicular axis.
DS0026 MISMATCH OF ANGULAR
AXIS(D.C.S)
On angular axis control, one of the
angular/perpendicular axes is the scale with ref-pos, and
the other of them is not the scale with ref-pos. Such
system is not admired.
DS0027 MISMATCH OF SYNCHRONOUS
AXIS(D.C.S)
Master/slave axes of feed axis synchronization control,
one of them is the linear scale with distance-coded
reference marks, and the other of them is not the linear
scale with distance-coded reference marks.
Please establish reference position with the input signal
SYNCn<G138>, SYNCJn<G140> or pameter setting to
0.
DS1448 ILLEGAL PARAMETER (D.C.S.) The setting value of parameter for reference marks is
satisfied the following any conditions.
- The absolute-position detection function is enabled.
- Either parameter 1821 (mark-1 interval) or parameter
1882 (mark-2 interval) is set to 0.
- Parameters 1821 and 1882 have identical settings.
- The difference between the settings made for
parameters 1821 and 1882 is greater than or equal to
twice either setting.
- The setting value of parameters 1883 and 1884 are
over the valid data range.
DS1449 REFERENCE MARK ARE DIFFERENT
FROM PARAMETER
In case of distance coded linear scale I/F, the actual
interval of reference marks is different from parameter
(No.1821,1882) setting value.