A-79253E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
4/18
Page
FANUC Series 30i-MODEL A
Distance coded linear scale interface
Procedure for establishing a reference position
through automatic operation
If an automatic reference position return (G28) is specified before a
reference position is not established, steps (3) to (5) above are performed
automatically.
After the reference position is established, the automatic reference position
return is performed.
Stopping the operation for establishing a reference
position
The operation for establishing a reference position is stopped if any of
the following operations is performed in steps (3) to (5), described above.
- Reset
- Setting the feed axis direction selection signal (+J1, -J1, +J2, -J2, etc.) to
0
If any of the following operations is performed during the operation of
automatic reference position return (G28) before a reference position is not
established, the operation for establishing a reference position stops:
- Reset
- Performing feed hold during movement from an intermediate position
If the operation for establishing a reference position is stopped by an
operation other than a reset, the operation for establishing a reference
position must be reset and resumed.
Reference Position Return
(1) When the reference position is not established and the axis moved by
turning the feed axis direction signal (+J1,-J1,+J2,-J2,...) to "1" in REF
mode, the reference position establishment procedure is executed.
(2) When the reference position is already established and the axis is
moved by turning the feed axis direction signal (+J1,-J1,+J2,-J2,...) to
"1" in REF mode, the axis is moved to the reference point without
executing the reference position establishment procedure.
(3) When the reference position is not established and the reference
position return command (G28) is executed, the reference position
establishment procedure is executed. The next movement the axis
depends on the setting of PRM No.1818#0(RFS).
(4) When the reference position is already established and the reference
position command (G28) is executed, the movement of the axis depends
on the setting of PRM No.1818#1(RF2).