B-65282EN/05 9.CONNECTION
- 169 -
9.3 CABLE CONNECTION DETAILS
9.3.1 Power Supply Module Connection Diagram
PSM (200-V input series)
PSM
TB1
K2
GND
K7
K69
CX4
(RIGHT)
CXA2A
Emergency stop
SPM,SVM
TB2(CZ1)
K1
K3
K6
Control power
supply
K70
CX1A
(LEFT)
CX3
(LEFT)
AC
REACTOR
MCC
CIRCUIT
BREAKER
2
Lightning surge
protector
3φ, 200 to 240 V
K11
FANMOTOR
FOR MOTOR
(Flange)
CIRCUIT
BREAKER
1
NOTE
1 Always install the circuit breakers, magnetic
contactor, and AC reactor.
2 To protect the equipment from lightning surge
voltages, install a lightning surge protector across
each pair of power lines and across each power
line and the grounding line at the power inlet of the
power magnetics cabinet. See Appendix A for
details.
3 Always connect the control power supply cable to
the CX1A. If it is connected to the CX1B, fuses
inside the unit may below.
4 See Section 5.2 for the type of the cable to be used
for making a connection to a frame ground.