9.CONNECTION B-65282EN/05
- 214 -
9.3.3.4 Details of cable K70
Connect the SPM flange or SPMC flange to the grounding plate
through a grounding cable. (Protective ground connection)
For connection with the SPM or SPMC, use the crimp terminal
selected according to the following table.
200-V input series
Amplifier model
Terminal
screw
Rigid torque
SPM-2.2i, SPM-5.5i, SPM-11i,
SPM-15
i, SPM-22i, SPM-26i, SPM-30i
SPMC-2.2i, SPMC-5.5i, SPMC-11i,
SPMC-15
i, SPMC-22i
M5 2 to 2.5Nm
SPM-45i, SPM-55i
M6 3.5 to 4.5Nm
See Subsection 9.3.1.7. for details of the cable K70.
400-V input series
Amplifier model
Terminal
screw
Rigid torque
SPM-5.5HVi, SPM-11HVi, SPM-15HVi,
SPM-30HV
i, SPM-45HVi
M5 2 to 2.5Nm
SPM-75HVi, SPM-100HVi
M6 3.5 to 4.5Nm
See Subsection 9.3.1.7. for details of the cable K70.
9.3.3.5 Details of cable K11
See FANUC AC SPINDLE MOTOR αi series DESCRIPTIOPNS (B-
65272EN) for details of this Subsection.