B-65282EN/05 APPENDIX B.CABLES
- 311 -
B.4 COMPOSITE 12-CORE CABLE
Specifications
Item Unit Specifications
Product No. – A66L-0001-0286
Manufacturer –
Hitachi Electric Cable Co., Ltd.
Oki Cable, Ltd.
Rating – 80°C, 30V
Conductor, braid-shielded wire,
drain wire
– Strand wire of tinned annealed copper (JIS C3152)
Insulator – Heat-resistant flame-retardant vinyl
Material
Sheath – Oilproof, heat-resistant, flame-retardant vinyl
Number of wires (wire nos.) Cores 6 (1 to 6) 6 (three pairs) (7 to 9)
Size mm
2
0.5 0.18
Structure
Conductors
/mm
20/0.18 7/0.18
Conductor
Conductors mm 0.94 0.54
Standard thickness (The
minimum thickness is at least
80% of the standard thickness.)
mm 0.25 0.2
Insulator
Outside diameter mm 1.50 0.94
Outside diameter mm 1.88
Direction of lay – LeftTwisted pair
Pitch mm 20 or less
Lay –
Twist the wires at an appropriate pitch so the outermost
layer is right-twisted, and wrap tape around the outermost
layer. Apply a cable separator as required.
Lay diameter mm 5.7
Size mm
2
0.3
Structure Wires/mm 12/0.18Drain wire
Outside diameter mm 0.72
Element wire diameter mm 0.12
Thickness mm 0.3
Braid density % 70
Shield braid
Outside diameter mm 6.3
Color – Black
Standard thickness (The
minimum thickness is at least
85% of the standard thickness.)
mm 1.1
Sheath
Outside diameter mm 8.5Max.9.0(1)
Standard length m 100
Packing method – Bundle
Resistance of conductor (at
20°C) (wire nos.)
Ω/km 39.4 (1 to 6) 113 (7 to 9)
Insulation resistance (20°C) MΩ-km 15
Electrical
performance
Dielectric strength (AC) V/min 500
Flame resistance – Shall pass flame resistance test VW-1SC of UL standards.
NOTE
The maximum outside diameter applies to portions
other than the drain wire.