B-65282EN/05 9.CONNECTION
- 179 -
Table.9.3.1.2 Short Bar K2 Specifications
Module location Short bar length L
Short bar
thickness t
Cross-section area
(Note)
Unit of 300mm-wide 300mm 3.0mm 50mm
2
Unit of 150mm-wide 150mm 1.5mm 21mm
2
Unit of 90mm-wide 90mm 1.5mm 21 mm
2
Unit of 60mm-wide 60mm 1.5mm 21 mm
2
NOTE
1 Modules need not necessarily be connected with a
short bar (copper plate).
If the modules cannot be placed close to each
other, however, they cannot help being separated
from each other.
If you connect them with a power cable, however,
the cable may not be thinner than indicated below
and must be insulated with heat-resistant polyvinyl.
2 When the width is 300 mm (SPM-45i, SPM-55i,
PSM-55i, SPM-75HVi, SPM-100HVi, PSM-75HVi,
PSM-100HVi, or SVM1-360HVi), cabling needs to
be performed using the two screws at P and N. So,
use a dedicated short bar (A06B-6078-K841, two
each per set).