3.ORDERING INFORMATION B-65282EN/05
- 58 -
Specifications of power transformers manufactured by FANUC
Power transformer for PSM
Model
Item
PSM-5.5i PSM-11i PSM-15i PSM-26i, 30i
PSM-37i
PSM-55i
(at 45kw output)
Ordering drawing
number
A06B-6052-J001 A06B-6044-J006 A06B-6044-J007 A06B-6044-J010 A06B-6044-J015
FANUC drawing
number
A80L-0001-0496 A80L-0001-0313 A80L-0001-0314 A80L-0001-0352 A80L-0001-0452
Rated capacity 10kVA 20kVA 30kVA 45kVA 64kVA
380/415/460VAC
230VAC (The secondary is used as an autotransformer.)
Rated primary
voltage
+10% -15%, 50/60±1Hz, 3φ
15A (at 380V) 30A (at 380V) 46A (at 380V) 68A (at 380V) 97A (at 380V)
14A (at 415V) 28A (at 415V) 42A (at 415V) 63A (at 415V) 89A (at 415V)Rated primary current
13A (at 460V) 25A (at 460V) 38A (at 460V) 56A (at 460V) 80A (at 460V)
Rated secondary
voltage
200/220/230VAC
Rated primary current 29A 58A 87A 130A 185A
Voltage regulation at
the secondary
5%
Voltage deviation at
the secondary
±3%
Connection Y-Y connection
Insulation Class H (maximum allowable temperature : 180°C)
Ambient temperature 0 to 45°C
Allowable
temperature rise
135deg
Relative humidity Max. 95%RH
Type Dry type, natural air cooling type
Dielectric withstand
voltage
2000VAC, for 1 minute
Weight Max. 61kg Max. 115kg Max. 165kg Max. 260kg Max. 375kg
Outline drawing Fig.8.1.4(a) Fig.8.1.4(b) Fig.8.1.4(c) Fig.8.1.4(d) Fig.8.1.4(e)
Connection diagram
(Primary)
Secondar
(Neutral
point)