8. CONNECTION TO SETTING AND DISPLAY UNIT
B–63173EN/03
310
(10)The stand–alone type MDI is designed for those who are familiar
with conventional MDI operation. The LCD with a touch panel has
a virtual keyboard, so operation can be performed without using the
stand–alone type MDI. The stand–alone type MDI is different from
the conventional stand–alone MDI used with the Power Mate though
the MDI key layout is the same as that of the conventional
stand–alone MDI unit. (See Subsection 8.1.7.)
(11) The LCD with a touch panel is provided with rotary switch JA2. This
switch is designed for future functional expansion. Leave the switch
as factory–set. (Normally, the switch is set to 0.)
(12)Jumper terminals STM1 and STM2 are used to terminate the display
link. Normally, leave these terminals connected. (Disconnect these
terminals if the display link does not terminate. When the LCD with
a touch panel is not connected at an end of the display link,
termination of the display link is unnecessary in the LCD.)
(13)If the ambient temperature is low, the LCD luminance lowers. See
(10) in Subsection 8.4.1.
(14)The method of a special operation at power–on such as a memory all
clear operation differs from that with the conventional CRT/MDI.