3 - 12 Power Mate H Startup Guide - April 1997 GFK-1383A
3
Caution
Brakes are electrically released. You cannot command motion until the brake has been
energized. Brakes are for holding stationary loads only. Using the brake to stop a
moving load may cause damage or reduce the operating life of the brake.
Connecting the Servo Amplifier to the Line Filter (Optional)
Figures 3-9 and 3-10 illustrates the connection of the servo amplifier to the line filter. You must
supply the cable for both the connection between the line filter and the servo amplifier and for the
connection between the line filter and the power source (200-240Vac, 3 phase).
Use 4-conductor, 300V, 50°, Type SVT, SV, or SJ, UL or CSA-approved cable between the line
filter and the servo amplifier. The wire gauge used for connecting the line filter to the power
source must be sized based on the rating of the circuit breaker between the power source and the
line filter and the number of servos connected to the line filter.
12
11
10
9
8
7
6
5
4
3
2
1
19
18
17
16
15
14
13
a48024
1 2
3 4
5 6
R
S
T
R
S
T
Source
Power
To
Line Filter
Ground Lug
Connection Strip
a
Series Amplifier
Figure 3 - 9. αα Series Amplifier Connection to the Line Filter and Power Source
a48025
1 2
3 4
5 6
R
S
T
R
S
T
Source
Power
To
Line Filter
Connection Strip
b
Series Amplifier
Ground Lug
L3
L2
L1
CX11-
Figure 3 - 10. ββ Series Amplifier Connection to the Line Filter and Power Source