5 - 2 Power Mate H Startup Guide - April 1997 GFK-1383A
5
For example, when you see:
SYSTEM
+
PARAMETER
+
OPRT
+
+
+
it indicates that you should press the SYSTEM key, then the PARAMETER softkey, followed by
the OPRT softkey. Then, position the cursor on the desired item, type the string of characters
1234, and press the INPUT key. This will input the value 1234 at the point where the cursor is
located.
The following information explains how to enter parameter data using the various display
terminals available from GE Fanuc. Locate the section for the type of terminal you are using and
proceed with the setup.
Setting Parameters from the DPL/MDI
To enter parameter information from the DPL/MDI, you must first enable the parameters to be
changed. This enable is called Parameter Write Enable (PWE). When set to 1, you may change
parameters. When set to 0, no parameters can be changed.
Caution
Make sure that the Power Mate H is not running a program or moving the axes before
changing the PWE since this will stop program execution. We recommend that you
enter an EMERGENCY STOP condition before changing parameters.
Setting the PWE Bit
MENU
VAR
+
1
+
INPUT
+
Press the MENU/VAR key until an H or a # is not displayed. Then, use the cursor keys to scroll
until PWE is displayed on the first line of the DPL/MDI display. When PWE is set to 1, Alarm
100 will appear, indicating PWE=1.
Note
To clear Alarm 100, simultaneously press the Cancel (CAN) and Reset keys on the
CRT/MDI unit or reset the PWE bit to zero after all parameter changes are complete.