Connecting Machine Input/Outputs
The Power Mate H motion system is shipped with a standard machine interface (ladder logic
program) stored in memory. The standard interface supports up to 4 axes. For systems with
higher axis counts the standard ladder will have to be modified. The standard interface is intended
to facilitate rapid startup of basic system configurations to the point where motors can be jogged.
It is not intended to perform all functions necessary to control a complete machine. However, the
standard interface can be used as a starting point for many applications.
This program also supports several available I/O interfaces:
1. Built-in I/O Card: 32 inputs/24 outputs installed as an optional card inside the Power Mate H
housing. Connections are made to separately mounted screw terminal adapter boards
connected to the Power Mate H via ribbon cables.
2. I/O Unit Model A: Up to 1024 inputs/1024 outputs can be assembled using I/O modules
which plug onto a separately mounted rack. The rack includes an interface module which
uses GE Fanuc I/O Link to connect to the Power Mate H.
3. Genius I/O: 16 inputs/2 outputs installed as an optional card inside the Power Mate H
housing. This card also allows the Power Mate H to be connected as a slave node on a GE
Fanuc Genius network. Connections are made to a separately mounted screw terminal adapter
board connected to the Power Mate H via a ribbon cable.
Note
Parameter 3001#3 (BIO) enables the Power Mate H to work with the proper I/O
configuration. Be sure to set this parameter for the I/O option you are using, as
defined in Table 5-1, Basic Parameter Settings.
A list and brief definition of the I/O functions supported by the standard interface are shown in
Table 3-3 and Table 3-4 below. Each I/O configuration uses a different hardware interface and
different I/O addresses. Each I/O option uses the same basic mnemonic name for each I/O
function shown in Table 3-3 but with a suffix to indicate the I/O option. For example, a "B" suffix
indicates Built-in I/O; an "A" suffix indicates I/O Unit Model A, and a "G" indicates Genius I/O.
The following sections show connection details and signal lists for each option. Once you have
determined which I/O configuration you have, proceed to the appropriate section and connect your
machine control I/O.
Note
An asterisk (*) preceding a name indicates active low logic. When the input is
active (switch closed), the input condition is not active.