A-79595E
Title
Draw
No.
Ed. Date Design Description
Date May.24.’04 esig. Apprv.
19/33
Sheet
FANUC Series 30i-MODEL A
Live Tool Control With Servo Motor
Least input increment
Least command
increment
0.00001mm (diameter specification) 0.000005mm Millimeter
input
0.00001mm (radius specification) 0.00001mm
0.000001inch (diameter specification) 0.000005mm
Millimeter
machine
Inch input
0.000001inch (radius specification) 0.00001mm
0.00001mm (diameter specification) 0.0000005inch Millimeter
input
0.00001mm (radius specification) 0.000001inch
0.000001inch (diameter specification) 0.0000005inch
Inch
machine
Inch input
0.000001inch (radius specification) 0.000001inch
IS-D
Rotation axis 0.00001deg 0.00001deg
Least input increment
Least command
increment
0.000001mm (diameter specification) 0.0000005mm Millimeter
input
0.000001mm (radius specification) 0.000001mm
0.0000001inch (diameter specification) 0.0000005mm
Millimeter
machine
Inch input
0.0000001inch (radius specification) 0.000001mm
0.000001mm (diameter specification) 0.00000005inch Millimeter
input
0.000001mm (radius specification) 0.0000001inch
0.0000001inch (diameter specification) 0.00000005inch
Inch
machine
Inch input
0.0000001inch (radius specification) 0.0000001inch
IS-E
Rotation axis 0.000001deg 0.000001deg
(2) M series
Least input increment, Least command increment
Increment system
IS-A IS-B IS-C IS-D IS-E Unit
Millimeter machine 0.01 0.001 0.0001 0.00001 0.000001 mm
Inch machine 0.001 0.0001 0.00001 0.000001 0.0000001 inch
Rotation axis 0.01 0.001 0.0001 0.00001 0.000001 deg
Setting command multiply (CMR), detection multiply (DMR),
and the capacity of reference counter
Least
command
increment
×
CMR
Error counter
DA
Converter
×
DMR
Position
detector
Reference counter
Command pulse
Feedback pulse
Detection
unit
To
velocity
control
Set CMR and DMR so that the pulse weight of + input (command from the
CNC) into the error counter matches the pulse weight of – input (feedback
from the position detector).
[Least command increment]/CMR = [Detection unit]
= [Feedback pulse unit]/DMR