4/18
EDIT
DATE
DESIG.
DESCRIPTION
CUST.
SHEET
TITLE
DRAW.NO.
FANUC Power Mate i-MODEL H
CONNECTION MANUAL (FUNCTION)
High Speed Skip function
B-63173EN-1/01-26
01
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
SignalSignal
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
High-speed skip signalHigh-speed skip signal
DI30 DI30 ~~ DI37 DI37
<X1003#0<X1003#0∼∼ #7>#7>
[Classification][Classification] Input signal
[Function][Function] These signals interrupt skip cutting. That is, the position, where a
skip signal turns to “1” in a command program block containing
G31, G31P1 to P8, is stored in a custom macro variable, and the
move command of the block is interrupted at the same time.
Furthermore, in a block containing G04, G04Q1 to Q8, the dwell
command of the block is interrupted by this signal.
In either case, until all other commands (such as miscellaneous
functions) of the block are completed, machining never proceeds
to the next block.
Which of the eight skip signals is applicable to blocks containing the
G codes can be determined by parameter (No. 6202 to 6206, No 6270
to 6273). The eight skip signals can correspond to the G codes on a
one-to-one basis. One skip signal can also be made applicable to
multiple G codes. Conversely, multiple skip signals can be made
applicable to one G code.
[Operation][Operation] When a skip signal turns to “1”, the control unit functions as
described below.
•When a block contains a G code for skip cutting (from G31,
G31P1 to P8), and the skip signal is made applicable to the
command by parameter setting, the control unit reads and
stores the current position of the specified axis at that time.
The control unit stops the axis, and then cancels the remaining
distance that the block was supposed to be moved.
When a block contains a G04, or G04Q1 to Q8 for dwell, and
the skip signal is made applicable to the command by
parameter setting, the control unit stops dwell operation, and
cancels any remaining dwell time.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Signal addressSignal address
#7 #6 #5 #4 #3 #2 #1 #0
X1003 DI37 DI36 DI35 DI34 DI33 DI32 DI31 DI30