14/18
EDIT
DATE
DESIG.
DESCRIPTION
CUST.
SHEET
TITLE
DRAW.NO.
FANUC Power Mate i-MODEL H
CONNECTION MANUAL (FUNCTION)
High Speed Skip function
B-63173EN-1/01-26
01
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
ParameterParameter
[Data type][Data type] Bit type
SLS While the high-speed skip signals are input, the high-speed
skip signals are :
0 : not available
1 : available
SRE In case the status trigger method for high-speed skip signals is
selected (bit6 of No.6209 = 0) :
0 : The signal is considered to be input at the status “1”.
1 : The signal is considered to be input at the status “0”.
[Data type][Data type] Bit type
IGX When the high-speed skip function is used, SKIP, SKIP2 to
SKIP4, and SKIPP (G006#6) are:
0 : Enabled as skip signals.
1 : Disabled as skip signals.
#7 #6 #5 #4 #3 #2 #1 #0
6200
SRE SLS
The skip signals (The skip signals (SKIP, SKIP2 SKIP, SKIP2 ∼∼SKIPSKIP44) are) are
availableavailable irrespective of whether irrespective of whether this parameterthis parameter
is
set.set. If the parameter If the parameter IGX IGX (bit 4 of (bit 4 of No.6201No.6201) is set) is set
to 1, these signals are not available.to 1, these signals are not available.
#7 #6 #5 #4 #3 #2 #1 #0
6201
IGX
The following parameters must be set, if the aboveThe following parameters must be set, if the above
parameter is set to parameter is set to ““11”” and the high-speed skip and the high-speed skip
signals are available.signals are available.
No.8731, 8732, 8733No.8731, 8732, 8733