5.CONNECTIONS FANUC AC SPINDLE MOTOR α(HV)iT SERIES B-65272EN/04
- 334 -
5.1 CONNECTION OF THE POWER, FAN MOTOR, AND MZi
SENSOR SIGNAL LEADS
Cables for power lead and fan motor are connected to the terminal
block.
MZi sensor signal or thermostat signal use a connector manufactured
by Tyco Electronics AMP.
The connector housing and the connector are attached to the motor.
Power lead Cooling fanSize of screws used in
the terminal
block
Model
U,V,W,G X,Y,Z FMU,FMV,FMW FMU,FMV
α1.5/15000HViT
M5 - M4 M4
α2/15000HViT
M5 - - Screw-less terminal block
α3/12000HViT
M5 - - Screw-less terminal block
α6/12000HViT
M5 M5 Screw-less terminal block -
α8/12000HViT
M5 M5 Screw-less terminal block -
α8/15000HViT
M5 M5 Screw-less terminal block -
α15/10000HViT
M5 M5 Screw-less terminal block -
α15/12000HViT
M5 M5 Screw-less terminal block -
α22/10000HViT
M5 M5 Screw-less terminal block -
Cable for the fan motor
For the fan motor current value and cable specifications, refer to
Section I.4.3, “FAN MOTOR CONNECTION” in this manual.