4.CONNECTIONS FANUC AC SPINDLE MOTOR α(HV)iL SERIES B-65272EN/04
- 360 -
4.3 COOLING
Cooling conditions
Item
α
αα
α8/20000HViL α
αα
α15/15000HViL α
αα
α26/15000HViL
Cooler capacity
kw
(kcal/h)
2.3 to 3.5
(*1)
(2000 to 3000)
2.9 to 3.5
(*1)
(2500 to 3000)
2.9 to 4.1
(*1)
(2500 to 3500)
Liquid coolant
1. Liquid
2. Liquid additive (example: 2% SHELL DONAX CC)
(*2)
Liquid coolant flow L/min 10 or more
Liquid coolant pressure kPa(kgf/cm
2
) 490 or lower (5 or lower) (as measured at the cooling pipe inlet)
Liquid coolant viscosity m
2
/sec(cSt) 1.0 × 10
-5
or lower (10 or lower)
Liquid coolant specific heat J/g⋅K1.87
Liquid coolant density g/cm
3
0.78
Liquid coolant temperature
(*3)
Room temperature +0°C to +10°C
(as measured at the cooling pipe inlet)
(*1) This cooler capacity meets the corresponding CE marking
standard.
(*2) It has been confirmed that a dilute solution with 2% of "SHELL
DNAX CC" made by SHELL is usable for cooling.
(*3) If the temperature of the liquid coolant is lower than the room
temperature as measured at the cooling pipe inlet, it is likely that
condensation may occur in the motor. Be sure to strictly observe
the specified temperature.