4.NOTES ON INSTALLATION SPECIFICATIONS FOR THE αi SERIES B-65272EN/04
- 14 -
NOTE
1 A foot mounting type motor has no oil seal. When an oil seal is
required, add #0002 to the drawing number of the motor. An oil
seal cannot be attached to any high-speed model, however. For
details, refer to "Order List" (B-65271EN).
Example)
Model α12/7000i (foot mounting type, with no key,
rearward exhaust)
A06B-1408-B200
A06B-1408-B200#0002 (with oil seal)
2 When the oil seal is not exposed to lubricant, remove the coil
spring of the oil seal to decrease the friction between the lip and
shaft.
There is no problem with dry dust sealing.
If the motor is turned at high speed with the contact section
between the oil seal and shaft being dry, the contact section can
make an abnormal sound (interfering sound), or the lip can be
damaged.