3
1
4
5
6
7
8
9
10
2
224
2) For reader/puncher interface
Number
Contents Remarks
0024 Port for communication with the PMC ladder
development tool (FAPT LADDER–II)
0 : HSSB (COP7)
1 : RS–232C serial port 1 (JD36A)
2 : RS–232C serial port 2 (JD36B)
3 : Remote buffer interface (RS–232C) (JD28A)
0100 Common to each channel
#1 CTV : TV check in the comment section of a program
is performed (0)/not performed (1)
#3 NCR : When output EOB by ISO code, LF, CR, CR
(0)/CR output (1)
#5 ND3 : DNC operation is performed to read blocks one
by one (0)/until the buffer becomes full (1).
#6 IOP : Input/output of an NC program is stopped by
resetting the CNC (0)/by pressing the [STOP]
soft key (1).
#7 ENS : Reading of data by EIA code, if NULL code is
red in the data, ignore it (0)/make alarm (1)
ALM001
0101 Parameter relating to CHANNEL 1
(I/O CHANNEL=0)
#0 SB2 : Number of stop bit is 1 bit (0)/2 bits (1)
#3 ASI : Data input by EIA or ISO code (0)/ASCII code
(1)
#7 NFD : FEED before & after of data is output (0)/not
output (1)
0102 Spec. No. of I/O devices of CHANNEL 1
(I/O CHANNEL=0)
0 : RS-232-C (Used control codes DC1 to DC4)
1 : FANUC CASSETTE B1/B2
2 : FANUC CASSETTE F1
3 : FANUC PROGRAM FILE Mate, FANUC FA
Card, FSP-H, FANUC FLOPPY CASSETTE
4 : RS-232-C (Control codes DC1 to DC4 are not
used.)
5 : PORTABLE TAPE READER
6 : FSP-G, FSP-H, FANUC PPR
0103 Baud rate setting of CHANNEL 1
(I/O CHANNEL=0)
1 : 50 Baud 7 : 600 Baud
2 : 100 Baud 8 : 1200 bps
3 : 110 Baud 9 : 2400 Baud
4 : 150 Baud 10 : 4800 Baud
5 : 2000 bps 11 : 9600 Baud
6 : 300 Baud 12 :19200 Baud
0111 Parameter relating to CHANNEL 1
(I/O CHANNEL=1)
PRM0101
0112 Spec. No. of I/O devices of CHANNEL 1
(I/O CHANNEL=1)
PRM0102