1. SCREEN DISPLAY AND OPERATION
45
F Saving a FROM file to a memory card
(SYSTEM DATA SAVE screen)
NOTE Only user files, such as the ladder and macro P-code programs,
can be saved to a memory card. System files, such as NC BASIC,
cannot be saved.
(1) Select the SYSTEM DATA SAVE screen.
1 Using the [UP] or [DOWN] soft key, position the cursor to 4.
SYSTEM DATA SAVE.
2 Press the [SELECT] soft key.
When more than one board is connected to the NC, the SLOT
CONFIGURATION screen appears.
FROM files are listed on the screen as follows:
SELECT
[][][][][]
YES NO UP DOWN
SYSTEM DATA SAVE
[ BOARD : MAIN ]
FILE DIRECTORY
1. NC BASIC(10)
2. DG SERVO(1)
3. PMC0BSC(2)
4. PMC–RB(1)
5. NC1 OPTN(8)
6. END
***MESSAGE***
SELECT FILE AND HIT SELECT KEY.
(2) Select the file to be saved.
1 Using the [UP] or [DOWN] soft key, position the cursor to the
desired file name.
2 Press the [SELECT] soft key.
D To quit and return to the SYSTEM MONITOR MAIN MENU
screen, position the cursor to END, then press the [SELECT]
soft key.
3 A confirmation message appears at the bottom of the screen. To
save the file, press the [YES] soft key. To abandon the saving,
press the [NO] soft key.
Upon pressing the [YES] soft key, the specified file is saved to the
memory card.
Once the file has been saved, “HIT SELECT KEY”
appears at the bottom of the screen, together with the
name assigned to that saved file.
SELECT
[][][][][]
YES NO UP DOWN
FILE SAVE COMPLETE. HIT SELECT KEY.
SAVE FILE NAME:PDIM05. 000
Name assigned to
the saved file