3
1
4
5
6
7
8
9
10
2
298
Number RemarksContents
4950 Spindle positioning T series
#0 IOR : Resetting the system in the spindle positioning
mode does not releases the mode (0)/releases
the mode (1)
#1 IDM : The positioning direction for the spindle using a
M code is the positive direction (0)/the negative
direction (1)
#2 ISZ : When an M code for orientation is specified,
orientation by canceling rotation mode is
performed (0)/not performed (1).
#5 TRV : Rotation direction of spindle positioning is set
to the positive direction (0)/the reverse
direction (1)
#6 ESI : Spindle positioning conforms to the
conventional specification (0)/extended
specification (1).
#7 IMB : Semi-fixed angle positioning by M code follows
specification A (0)/specification B (1).
4960 M code specifying the spindle orientation
4961 M code releasing the spindle positioning mode
4962 M code specifying the angle for the spindle
positioning
4963 Basic rotation angle specified by a M code in
the spindle positioning mode
T series
4964 Number of M codes for specifying a spindle
positioning angle
4970 Servo loop gain of the spindle
4971 Servo loop gain multiplier of the spindle for
gear 1
4972 Servo loop gain multiplier of the spindle for
gear 2
4973 Servo loop gain multiplier of the spindle for
gear 3
4974 Servo loop gain multiplier of the spindle for
gear 4