3
1
4
5
6
7
8
9
10
2
348
55) Parameters for two-path control
Number
Contents Remarks
8100 2-path
control
#0 RST : Reset key on the MDI panel effective for both
paths (0)/for the tool post selected by the path
select signal (1)
#1 IAL : When an alarm is raised in one tool post in the
automatic operation mode, the other path
enters the feed hold state and stops (0)/
continues operation without stopping (1)
#5 COF : A separate tool compensation memory area is
used for each path (0)/a common tool
compensation memory area is shared by the
tool posts (1).
#6 DSB : The special single block function is disabled
(0)/enabled (1).
T series
T series
T series
8110 Queuing M code range (minimum value)
2-path
8111 Queuing M code range (maximum value)
con
ro
56) Checking Interference between tool posts (two–path control)
Number
Contents Remarks
8140 Checking interference between tool posts
(two–path control)
T series
(2-path
control)
#0 TY0 : Specifies the relationship between the
#1 TY1 : coordinate systems of the two tool posts.
#2 IT0 : When offset number 0 is specified by the T
code, checking interference between tool posts
is stopped until an offset number other than 0 is
specified by the next T code (0)/checking
interference between tool posts is continued
according to the previously specified offset
number (1)
#3 IFM : Specifies whether interference (two–path
control) between tool post is checked (0)/is not
checked (1) in the manual operation mode
#4 IFE : Specifies whether interference (two–path
control) between tool posts is checked (0)/is
not checked (1)
#5 ZCL : Specifies whether interference along the Z axis
is checked (0)/is not checked (1)
T series
T series
T series