Number RemarksContents
1816 Parameter relating to detection multiply <Axis>
#4 DM1 :
#5 DM2 :
#6 DM3 :
DM3 DM2 DM1 DMR DM3 DM2 DM1 DMR
0 0 0 1/2
0011
0 1 0 3/2
0112
1 0 0 5/2
1013
1 1 0 7/2
1114
Move amount per one rotation of the motor
Position feedback pulse per one rotation of
the motor DMR
Detection unit =
Flexible
feed gear
In case of
parameter
(No. 2084
and 2085
are not
used.)
1817 Tandem control <Axis>
#6 TAN : Tandem control is not applied (0)/applied (1).
1819 Follow-up, feed-forward <Axis>
#0 FUP : When the servo system is turned off, a
follow-up operation is performed based on
*FLWU (0)/is not performed (1).
#1 CRF : When servo alarm No.445 (software
disconnection), No.446 (hardware
disconnection), No.447 (hardware
disconnection (separate type)), or No.421
(excessive dual position feedback error) is
issued, the reference position setting remains
as is (0)/the system enters the reference
position undefined state (1)
#7 NAH : In look-ahead control mode, the advance
feed-forward function is used (0)/not used (1).
M series
1820 Command multiply for each axis (CMR)
CMR =
CMR t 1 Setting value = (1/CMR) +100
CMR y 1 Setting value = 2 CMR
Least command increment
Detection unit
<Axis>
1821 Reference counter capacity for each axis
[Detection unit]
<Axis>
1825 Servo loop gain for each axis [0.01 sec
–1
] <Axis>
Std=3000
1826 Inposition width for each axis [Detection unit] <Axis>
1827 Inposition width for successive cutting feed
blocks for each axis [Detection unit]
<Axis>
T series
PRM
1801#4
1828 Positioning deviation limit for each axis in
movement [Detection unit]
Setting value =
Rapid traverse
60 PRM 1825
1
Detecting unit
1.2
<Axis>
PRM 1420
PRM 1825
1829 Positioning deviation limit for each axis in the
stopped state [Detection unit]
<Axis>
Std=5000