8. PARAMETERS
243
Number RemarksContents
1802 Speed control based on the servo motor T series
#0 CTS : Speed control based on the servo motor is not
applied (0)/applied (1).
#1 DC4 : When the reference position is established on
the linear scale with reference marks. An
absolute position is established by detecting
three reference marks (0)/four reference marks
(1)
#5 DPS : In speed control based on the servo motor, a
position coder is used (0)/not used (1).
T seres
T series
1803 Torque control
#0 TQI : While torque restriction is applied, in–position
check is performed (0)/not performed (1)
#1 TQA : While torque restriction is applied, checking for
an excessive error in the stopped state/during
movement is performed (0)/not performed (1)
#4 TQF : When torque control is performed by an axis
control command of the PMC axis control
function, follow–up operation is not performed
(0)/performed (1)
1804 VRDY OFF ignore signal
#1 BLC : During circular interpolation by jog feed
(manual circular interpolation function), the
backlash acceleration function is, disabled (0)/
enabled (1)
#4 IVO : When an attempt is made to release an
emergency stop while the VRDY OFF alarm
ignore signal is 1, the emergency stop state is
not released until the VRDY OFF alarm ignore
signal is set to 0 (0)/the emergency stop state
is released (1)
#5 ANA : When an abnormal load is detected for an axis:
movement along all axes is stopped, and a
servo alarm is output (0)/no servo alarm is
output, and movement along only the axes of
the group containing the axis with the abnormal
load is stopped in interlock mode (1)
#6 SAK : When the IGNVRY signal is 1 or the IGNVRYx
signal for each axis is 1, SA is set to 0 (0)/
1 (1).
Param
1881
1815 Parameter relating to position detector <Axis>
#1 OPT : A separate pulse coder is not used (0)/
used (1)
#2 DCL : As a separate position detector, the linear scale
with reference marks is: not used (0)/used (1)
#4 APZ : When the absolute position detector is used,
machine position and absolute position
transducer is not corresponding (0)/
corresponding (1)
#5 APC : Position transducer is incremental position
transducer (0)/absolute pulse coder (1)