Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 1025 -
FANUC Series 16/18/16i/18i/21i C Executor
1998.11.18 FANUC LTD.
C Executor diagnostics information
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Descriptions of diagnosis
Data number Data
+--------+ +-------------------------------------------------------+
| 0045 | | C Executor status |
+--------+ +-------------------------------------------------------+
Data format : byte type
Data range : 0 through 255
C Executor status.
0: Normal.
2: Invalid FROM file. (header)
3: Power-on with pushing [M] and [0] keys to ignore C Executor.
5: Insufficient SRAM. (Increase SRAM size.)
Or C Executor library version mismatch. (Use new version of C
Executor library.)
6: Internal error.
7: Internal error.
9: Internal error.
10: C Executor library version misatch. (Use new version of C Executor
library.)
11: Invalid FROM file. (CRC error)
(NOTE) This information is same as the value which is stored at
[0F6E17] of CNC's memory.
Data number Data
+--------+ +-------------------------------------------------------+
| 0046 | | Execution time of High-Level task |
+--------+ +-------------------------------------------------------+
Data format : word type
Data unit : 1/512 [msec]
Data range : 0 through 4095
This shows execution time of C Executor's High-Level task.
[ End of dgn.txt ]