Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 1087 -
Example: The trigger breaks on at the address 803456H when the data
of1234H(byte) is equal to 12H.
No.8980 = 11010000 : Instruction trigger.
No.8981 = 8402006 : Trigger address 803456H
No.8982 = 987700 : Data address 0F1234H
No.8983 = 18 : Data 12H
No.8984 = 6 : CMP byte trigger.
When the trigger break on, the content of all register and stack are
saved in RAM area of 128 byte.
The information can be examined by PMC "Content of memory".
The RAM address of FS16-B/C is from 0F4AE4H to 0F4B63H.
The RAM address of i series is from 5102E4H to 510363H.
The four bytes data of the address specified by No.8982 are set in
the head four bytes of RAM when trigger is broken.
* The head four bytes are set even if break on condition is
unconditional (parameter No.8984 =0). So pleas examine the
data written in RAM by write trigger or the data of the
specified address by execution trigger.
* Please do not specify wrong address because the address shown
by parameter No.8982 is read even if the break on condition is
unconditional (parameter No.8984 = 0). And then BUS-Error will
be generated.
+---------------------------------------------------------------------+
| Attention |
| |
| At read or write trigger in multi function mode, |
| when you specify the same address as the trigger point and the |
| condition point, the system will be hung up. Because the same |
| is read in debug IRQ routine again and double fault is generated |
+---------------------------------------------------------------------+
c) Continue Mode.
In case of both a standard mode and the multi function mode, when
the bit5 of the parameter No.8980 set 1, it becomes Continue mode.
In case of continue mode, after the content of all register and
stack are saved in RAM, the same trigger condition is continued.
(Condition mode)
76543210
8980 0 1 DBCONT
DBCONT = 1: Continue mode.