Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 568 -
[Return]
0 Successful.
[Description]
Read the CNC's system configuration information.
The each informations are stored in each members of "odbsysc".
slot_no_p Physical slot number.
The physical slot numbers of installed modules
are stored in installing order. This list is
terminated by 0xFF. Any data after 0xFF are
invalid.
0x00 - 0x0F : Physical slot number (fore).
0x80 - 0x8F : Physical slot number (back).
slot_no_l Logical slot number.
The logical slot numbers of installed modules
are stored in installing order. This list is
terminated by 0xFF. Any data after 0xFF are
invalid.
0x00 - 0x0F : Logical slot number.
mod_id Module ID.
The module IDs of installed modules are stored
with binary format. Each data are stored in the
array element indexed by the physical slot number.
"**" is the inner information.
0x**3F : FILE
0x**45 : Graphic (CAP-II)
0x**46 : I/O board
0x**6D : CAP-II
0x**7F : RISC(64bit)
0x**90 : CNC
0x**94 : MMC-IV
0x**9A : Graphic (Standard)
0x**9C : SUB(TT)
0x**9D : PMC-RC
soft_id Software ID.
The software IDs of installed modules are stored
with binary format. Each data are stored in the
array element indexed by the physical slot
number.
0x0040 : CNC
0x0041 : PMC-RC
0x0042 : I/O board
0x0043 : SUB(TT)
0x0044 : RISC(64bit)
0x0045 : Graphic (Standard)
0x0046 : Graphic (CAP-II)
0x0049 : CAP-II
0x004A : Remote buffer
0x005E : MMC-IV