Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 674 -
This function doesn't check integrity of the screen index numbers to
be registered.
Re-registration of the user screen index numbers by calling of this
function again is allowable. In this case, this function must be
called under condition that any screen switching is disabled by
"crt_setswt" function.
For FS16i/18i, "C Executor screen" is added to each large classi-
fication of CNC screens. (CEXE-screen) CEXE-screen is exclusive
screen for C Executor. The CNC software doesn't use this screen.
By registering this CEXE-screen as user screen using this function,
the new user screen is added without replacing any existing CNC
screens.
[Example]
The following program registers all position screens
([ABS]/[REL]/[ALL]) as user's screen.
#include <crt.h>
void example( void )
{
int crt_table[] = { CRT_POS_ABS, /* POSITION/ABSOLUTE */
CRT_POS_REL, /* POSITION/RELATIVE */
CRT_POS_ALL /* POSITION/ALL */
} ;
crt_setuserscrn( scrn_tbl_size(crt_table), crt_table ) ;
}