Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 777 -
param->dc1_code define DC1 code (usually 0x11 )
param->dc2_code define DC2 code (usually 0x12 )
param->dc3_code define DC3 code (usually 0x13;
to be compatible with CNC, 0x93 )
param->dc4_code define DC4 code (usually 0x14 )
Specify open mode of the communication interface by the argument
"mode".
mode open mode
-------+---------------
"r" receive mode
"w" send mode
"rw" send/receive mode
Every parameter must have it's value specified. If not, correct
communication will not be done.
To utilize communication function with Serial Library, "Reader/Punch
Interface 1" option has to be equipped in the CNC. "Reader Punch
Interface 2" option is also required to use the second serial
communication channel.
If "1" is specified for param->dc_put, DC1 code(for receive mode) or
DC2 code (for send mode) is sent via communication channel.