PROGRAMMING
19. AXIS CONTROL FUNCTIONS
B–63124EN/01
316
When the power is turned on, compensation pulses are output for the slave
axis to match the machine position of the master axis with the machine
position of the slave axis. (This is enabled only when the absolute
position detection function is used.)
Compensation for out–of–synchronism (where the difference between
the master and slave axes in servo positional deviation is always
monitored and the servo motor for the slave axis is compensated to reduce
the difference) is not performed.
When the machine is manually returned to the reference position during
synchronous operation, both the master axis and the slave axis move
synchronously until the acceleration movement is complete. However,
grid detection thereafter is carried out independently.
D Synchronization
D Compensation for
out–of–synchronism
D Manual reference
position return