OPERATION
11. SETTING AND DISPLAYING DATA
B–63124EN/01
614
Method 2
Change the mode of the soft keys to the operation selection mode
using the [(OPERATION)] soft key. Enter the registration number
of the tool for which data is to be changed, then press the
[NO.SEARCH] soft key.
5 For absolute programming, enter the data and press the [INPUT]
soft key.
For incremental programming, enter an increment or decrement
and press the [+INPUT] soft key.
Tool numbers to be specified must have been registered on the tool
registration screen. Settings range from 0 to 9999.
The number of punch operations using each tool registered on the tool
number registration screen (see Item 11.4.3.2) can be displayed and
specified.
(1)Displaying the screen
1 Press the
OFFSET
SETTING
function key.
2 Press the
menu key several times until the [TOOL] soft key
appears.
3 Press the [TOOL] soft key to display the tool registration initial
screen.
4 Press the
menu key. Then press the [PUNCH TIMES] soft
key to display the screen for the number of punch operations.
TOOL SET (COUNT) O0010 N00000
NO. COUNT NO. COUNT NO. COUNT
001 23 011 0 021 0
002 23 012 110 022 36
003 15 013 0 023 0
004 20 014 2 024 0
005 2 015 13 025 24
006 8 016 0 026 0
007 0 017 0 027 0
008 0 018 42 028 0
009 40 019 0 029 0
010 0 020 0 030 0
>_
MDI **** *** *** 13:39:58
[ T.NUM. ][ T.CHG.][ T.CNT. ][ SHAPE ][(OPRT)]
Fig. 11.4.3.4 Screen for the Number of Punch Operations
The number indicated on the screen corresponds to the tool registration
number on the tool registration screen (see Item 11.4.3.2).
(2)Setting items from the MDI
1 Set the mode to MDI.
2 Press the
OFFSET
SETTING
function key. Then press the [SETTING] soft key
to enable the parameter write operation. The CNC indicates alarm
No. 100.
11.4.3.4
Displaying and setting
items on the screen for
the number of press
operations