B–63833EN/03
7. SERVO INTERFACE
92
COP10B
COP10A
CP11A
CNF1
Servo amplifier module
Optical fiber cable
Optical fiber cable
Separate detector interface unit 1
24VDC
CNC
COP10B
COP10A
Linear scale axis 1
Battery for absolute
separate detector
Servo card
COP10A
|
|
|
Linear scale axis 2
COP10B
COP10A
COP10B
COP10A
JF101
JF102
JF103
JF104
JA4A
Linear scale axis 3
Linear scale axis 4
Up to 2 axes with Series 0i Mate–TB
Up to 3 axes with Series 0i Mate–MB
Up to 4 axes with Series 0i–TB/MB
When a separate pulse coder or linear scale is used, a separate detector
interface unit, as shown above, is required. The separate detector
interface unit should be connected to the CNC control unit through an
optical fiber cable, as one of the units on the servo interface (FSSB).
Although the above figure shows the separate detector interface
connected in the final stage of the FSSB line, it can also be connected, at
the nearest location, to the CNC control unit. Or, it can be installed
between two servo amplifier modules.