5. DESCRIPTION OF PARAMETERS
(YP SERIES)
B–63200EN/03
87
15270 Low power detection value
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
[Standard setting] 0
If the actual laser output is less than this setting, an alarm is generated. If
the setting is 0, the alarm monitor is not executed.
15271 Alarm monitor start wait time
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
[Standard setting] 5000
Set the time from the start of beam output until the start of the low power
alarm monitor. If the setting is 0, the wait time is 5 seconds.
15272 Alarm monitor time width setting
[Data type] Two–word
[Unit of data] msec
[Valid data range] 0 to 99999999
[Standard setting] 0
Set the time from the start of the low power alarm monitor to its end. If the
setting is 0, the alarm monitor continues until the beam stops.
15273 Low power detection value (during power calibration operation)
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
[Standard setting] 0
If, during power calibration operation, the actual laser output is less than
this setting, an alarm is generated. If the setting is 0, the alarm monitor is
not executed.
5.5
LOW POWER
ALARMS