B–63665EN/01
1. DISPLAY AND OPERATION
91
#7
311
#6 #5
OPM
#4 #3 #2 #1 #0
[Data type] Bit
OPM Operating monitor display is:
0 : Disabled
1 : Enabled
3151 Axis number for which the first servo motor load meter is displayed
3152 Axis number for which the second servo motor load meter is displayed
3153 Axis number for which the third servo motor load meter is displayed
3154 Axis number for which the fourth servo motor load meter is displayed
3155 Axis number for which the fifth servo motor load meter is displayed
3156 Axis number for which the sixth servo motor load meter is displayed
3157 Axis number for which the seventh servo motor load meter is displayed
3158 Axis number for which the eighth servo motor load meter is displayed
[Data type] Byte
[Valid data range] 0, 1, ... number of controlled axes
These parameters specify the numbers of the axes for which load meters
for servo motors are to be displayed. Up to eight load meters can be
displayed. Set 0 for those axes for which no load meter is to be displayed.
1.11.2
Parameters