B–63665EN/01
1. DISPLAY AND OPERATION
65
#7
510
#6 #5 #4 #3 #2 #1 #0
DGN
This data indicates the internal Open CNC information (not available to
general users).
#7
511
#6 #5 #4 #3 #2 #1 #0
DGN
This data indicates the internal Open CNC information (not available to
general users).
#7
PA1512
#6
PA0
#5
BNK
#4 #3
THH
#2
THL
#1 #0
PRA
DGN
This data indicates the cause of a system alarm that has occurred in Open
CNC.
#0(PRA) 1 : A RAM parity error occurred in shared RAM.
#2(THL) 0 : The temperature of the harddisk of Open CNC is too low.
1 : Normal
#3(THH) 0 : The temperature of the harddisk of Open CNC is too high.
1 : Normal
#4 0 : Normal
1 : An NMI has occurred in HSSB.
#5(BNK) If bit 0 (PRA) is set to 1,
0 : An alarm occurred in the lower half of shared RAM.
1 : An alarm occurred in the upper half of shared RAM.
#6 (PA0) If bit 0 (PRA) is set to 1,
1 : An alarm occurred at an even–numbered address.
#7 (PA1) If bit 0 (PRA) is set to 1,
1 : An alarm occurred at an odd–numbered address.
Difference in the position error between the master and slave axes in simple
synchronas control
540
DGN
Difference in the position error between the master and slave axes in simple
synchronas control
541
DGN
D Open CNC
D Diagnostic data related
to simple synchronous
control