B–63665EN/01
6. EMBEDDED ETHERNET
243
7 The screen below is used to check the communication state of the
embedded Ethernet function and the error detection count of the
Ethernet controller.
ETHERNET MAINTENANCE
PAGE : 2/4
(NETWORK STATUS)
BAUDRATE 100MBPS / FULL DUPLEX
NETWORK DEVICE EMBEDDED PORT
(NETWORK STATUS : SEND)
COLLISION 0
CARRIER SENSE LOST 0
DELAY OVER 0
UNDERRUN ERROR 0
SEND PARITY ERROR 0
[ RETURN ][ ][ RESET ][ CLEAR ][ ]
ETHERNET MAINTENANCE
PAGE : 3/4
(NETWORK STATUS)
BAUDRATE 100MBPS / FULL DUPLEX
NETWORK DEVICE EMBEDDED PORT
(NETWORK STATUS : RECIEVE)
ALIGNMENT ERROR 0
ORC ERROR 0
OVERFLOW 0
FRAME LENGTH ERROR 0
RECIEVE PARITY ERROR 0
[ RETURN ][ ][ RESET ][ CLEAR ][ ]
The screen consists of two pages: one page for an error detection
count for transmission, and the other for an error detection count for
reception.
By pressing the [CLEAR] soft key on the first page, the error
detection counters for transmission and reception can be cleared to 0.
By pressing the [RESET] soft key, the current communication device
can be initialized and communication can be performed from the
initial state. Use this key to reset communication based on the
embedded Ethernet function.
8 The screen below is used to check the state of each task of the built–in
Ethernet function.