B–63665EN/01
3. INPUT AND OUTPUT OF DATA
133
6)
0102 Specification number of I/O device
0 RS–232–C (for other than the following)
1 FANUC Bubble cassette B1/B2
2 FANUCFloppy cassette F1
3 PROGRAM FILE Mate, FANUC FA Card adapter, FANUC
Floppy casette adapter, FSP–H, FANUC Handy File
4 Not used
5 Portable tape reader
6 FANUC PPR, FSP–G, FSP–H
7)
0103 Baud rate
1: 50 5: 200 9: 2400
2: 100 6: 300 l10: 4800
3: 110 7: 600 11: 9600
4: 150 8: 1200 12: 19200 [BPS]
3. Press soft key [(OPRT)] and soft key
4. Press soft key [READ] and [EXEC]. Then input of parameters are
started.
5. Because alarm 300 will generate for the system with absolute pulse
coder, set parameter 1815#5 to 0.
6. Alarm 300 is issued if the system employs an absolute pulse coder.
In such a case, perform reference position return again.