7. TROUBLESHOOTING
B–63445EN/01
132
3 What failure occurred ?
D Which alarm was displayed on the alarm display screen on the
setting and display unit?
(Check the axis along which an alarm has occurred for alarms 300
to 599.)
D For alarm 350: Examine number of diagnostic 202
For alarm 351: Examine number of diagnostic 203
For alarm 414: What does diagnostic display 200,201,204
indicate ?
D Is the screen on the setting and display unit correct ?
D If machining dimensions are incorrect
1) How large is the error ?
2) Is the position display on the CRT correct ?
3) Are the offsets correct ?
4 Other information
D Is there noise origin around machine?
If the failure has not occurred frequently, the cause may be external
noise to the power supply or inductive noise on machinery cables.
Operate other machines connected to the same power line and see
if noise come from the relays or compressors.
D Is it taken any countermeasure for noise in machine side?
Refer to Subsec. 2.2.3 ”Action Against Noise”.
D Check the following for the input power supply voltage :
1) Is there variation in the voltage ?
2) Are the voltages different depending on the phase ?
3) Is the standard voltage supplied ?
D How high is the ambient temperature of the control unit in the
cabinet?
Refer to manual about noise.
D Has excessive vibration been applied to the control unit?
(0.5 G or less during operation)
5 When you contact our service center, specify the following items :
1) Name of the unit
2) Name of the machine tool builder and type of machine
3) Software series/version of the Power Mate
4) Specifications of the servo amplifier and motor
(for a failure related to the servo)
5) Name and contact of the person who is most familiar with the
failure conditions
(for a failure related to the servo)
D See the drawing issued by the machine tool builder for the
locations of the Power Mate and servo.
D We use the following specification codes :
Servo amplifier : A06B–VVVV–HVVV
Servo motor : A06B–VVVV–BVVV
NOTE
V represents a number.
The above information is required by FANUC to determine
the cause of the failure. The information is used to
attempt to reproduce the failure at the service center.