APPENDIXA. ALARM LIST
B–63445EN/01
188
Number Contents and solutionMessage
5106 MEMORY CARD SIZE ERROR The capacity of the memory card is less than the size of the data to
be saved.
Use a memory card having a capacity greater than the size of the
data to be saved.
5107 MEMORY CARD DATA TYPE
ILLEGAL
The data stored on the memory card is not supported by the system.
Retry using a memory card containing data that is compatible with
the system.
5109 MEMORY CARD BATTERY ALARM A PMC communication error occurred during input/output to or from
the memory card. Retry input/output.
9) ALARM
Number Message Contents Counter plan Reference
1000 to
1999
A message created by the user or
machine tool builder, using the PMC
alarm message function, is dis-
played.
NOTE) On the DPL/MDI, only the
number is displayed.
Alarm generated by
the user or machine
tool builder using the
PMC
Apply appropriate
countermeasures as
explained in the
manual provided by
the machine tool
builder.
Manual provided by
machine tool builder
3000 to
3200
A message created by the user or
machine tool builder, using a custom
macro, is displayed.
NOTE) On the DPL/MDI, only the
number is displayed.
Alarm generated by
the user or machine
tool builder, using a
custom macro
Apply appropriate
countermeasures as
explained in the
manual provided by
the machine tool
builder.
Manual provided by
machine tool builder
5010 END OF RECORD EOR or % was read
without specifying a
program end com-
mand (M02 or M30).
10) Alarm messages (PMC)
This list contains alarms which do not occur in the Power Mate 0.
Message Contents and solution
ALARM NOTHING Normal status
ER00 PROGRAM DATA
ERROR(ROM)
The ladder program is not written correctly.
(solution) Write the ladder program again.
ER03 PROGRAM SIZE
ERROR(OPTION)
The size of ladder program exceeds the maximum size.
(solution) Please increase the option specification size.
Or, reduce the size of ladder program.
ER04 PMC TYPE UNMATCH The PMC model setting of the ladder program is not corresponding to an actual model.
(solution) Please change the PMC model setting by the offline programmer.
ER05 PMC MODULE TYPE
ERROR
The module type of the PMC engine is not correct.
(solution) Please exchange the module of PMC engine for a correct one.
ER07 NO OPTION
(LADDER STEP)
There is no step number option of LADDER.
ER17 PROGRAM PARITY A parity error occurred in RAM containing a ladder program.
(solution) Please edit the sequence program once on PMC. Check the operation.
Still the error occurs, exchange the RAM.
ER18 PROGRAM DATA ERROR
BY I/O
Transferring the ladder program from offline programmer was interrupted by the power
off etc.
(solution) Please clear the ladder program and transfer the ladder program again.
ER19 LADDER DATA ERROR Editing the LADDER was interrupted by the power off or by the switch to the CNC screen
by the function key etc.
(solution) Please edit LADDER once on PMC.
Or, please input LADDER again.