A-78500E
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
14/17
Date
Design
Descri
tion
Date
FANUC Series 16i /18i /21i -MB/TB
Trouble Diagnosis
Specifications
2001.07.02
M.Kobayashi H.Kochiya
02 2001.10.19 Exchan
e Bit ma
5.2.Operation
Change of position and magnification
When Soft key [G-ADJ.] is pressed, the following soft keys appear.
[<] [W.PRM ] [G-ADJ. ] [TRB_LV] [ ] [(OPRT)] [ ]
↓
[<] [ TIME→] [ TIME←] [H-DOBL] [H-HALF] [(OPRT)] [>]
↓
[<] [ CH-1↑ ] [ CH-1↓ ] [V-DOBL] [V-HALF] [(OPRT)] [>]
↓
[<] [ CH-2↑ ] [ CH-2↓ ] [V-DOBL] [V-HALF] [(OPRT)] [>]
[ TIME→]: Shift the waveform rightward.
[ TIME←]: Shift the waveform leftward.
[H-DOBL]: Double the time scale of the waveform
[H-HALF]: Half the time scale of the waveform
[V-DOBL]: Double the height scale of the waveform
[V-HALF]: Half the height scale of the waveform
[CH-1↑]: Shift the zero point upward
[CH-1↓]: Shift the zero point downward
[CH-2↑]: Shift the zero point upward
[CH-2↓]: Shift the zero point downward
The time scale is a common scale for the channel 1 and 2.
The position and magnification of the height scale can be set for each channel.