B–63083EN/02
9. CONNECTION TO FANUC I/O Link
177
Connectors that cannot be used on the cable side
Specification Manufacturer
Connector FI–20–CV7 Hirose Electric Co., Ltd.
Connector case and connector FI30–20S–CV7 Hirose Electric Co., Ltd.
Provide the CPD1 (IN) connector, shown below, with the power
necessary for the printed circuit board operation and that for DI operation.
To facilitate power division, the power is output to CPD1 (OUT) exactly
as it is input from CPD1 (IN). When power division is required, use
CPD1 (OUT).
01 +24V
02 0V
03
CPD1(IN)
01 +24V
02 0V
03
CPD1(OUT)
24 V power
supply
24 V power
supply
Recommended cable–side connector: A02B–0120–K324
(including the following connector housing and case)
(Housing: Japan AMP 1–178288–3)
(Contacts: Japan AMP 1–175218–5)
NOTE
The specification of the power supply connector CPD1 (IN)
is the same as that for CPD1 (OUT). There are no
indications on the printed circuit board to distinguish
between the IN and OUT connectors. Do not turn off the +24
V supply to the connector during operation. Turning off the
+24 V supply will cause a CNC communication alarm.
When turning on the power, the +24 V supply to the I/O
module must be turned on before or at the same time as the
power supply to the CNC. When turning off the power, the
+24 V supply to the I/O module must be turned off after or
at the same time as the power supply to the CNC.
9.6.2
Power Connection