B-63454EN/01 3. CONNECTION
-19-
- CD signal turned on at all times
- ER signal turned on at all times
- Data flow control XON/XOFF
- Automatic transmission speed adjustment enabled (to allow
automatic adjustment for connection at a maximum allowable
speed)
- Command echo not used
- Result code not used
Example of external modem setting
In this example, the use of the following modem is assumed for
command settings:
Panasonic: TO-BXF56K
Connect the modem to the personal computer, then start the terminal
software.
→ For connection between the personal computer and modem, refer
to the manuals provided with the personal computer and modem.
→ Windows is delivered with terminal software named Hyper
Terminal.
Using the terminal software, send the following commands, in the
listed order, to the modem:
Command Description
AT&F : Returns the settings to their initial values.
ATS0=3 : Sets the S register (to ring three times for automatic
termination).
AT&C0 : Turns on the CD signal at all times.
AT&D0 : Turns on the ER signal at all times.
AT&K4 : Applies XON/XOFF flow control.
AT&Y0 : Reads the settings of profile 0 when the power is on.
ATN1 : Enables automatic mode (for automatic transmission
speed determination).
ATE0 : Does not use command echo.
ATQ1 : Does not use result code.
AT&W0 : Saves the settings as profile 0.
In addition to the above, CNC parameter setting is required. See
Appendix B.
Setting example 2 (for the Series 15i)
- Automatic termination enabled
- Error correction connection display not provided
- Fixed terminal speed mode enabled
- CD signal turned on at all times
- ER signal turned on at all times
- Send data flow control XON/XOFF
- Receive data software flow XON/XOFF
- Receive data hardware flow not used
- Transmission speed specification (for setting of a transmission
speed on the CNC)