3. CONNECTION B-63454EN/01
-22-
3.3 CNC SETTING
3.3.1 Connecting a Modem Card to the CNC
For the Series 16i/18i/21i
Basically, no parameters need to be set. For transmission at a baud rate
other than 9600 bps, make the following settings:
- Bit 6 (MCB) of No. 0201 = 1
- No. 0203 = 1 to 12
(For details, see Appendix B.)
The optional reader/punch interface is not required.
NOTE
When a mobile telephone is used, the
communication baud rate is 9600 bps.
For the Series 15i
Make the following parameter settings:
- Bit 2 (ISP) of No. 0000 = 1
- Bit 3 (NCR) of No. 0000 = 1
- Bit 4 (EIA) of No. 0000 = 0
- No. 0020 through No. 0023 = 12
- No. 0040 = 17
- No. 5004 = 1 to 6
Set parameter No. 5110 through No. 5162 according to the setting of
parameter No. 5004. Set 3 as the I/O device specification number in
parameters No. 5110 through No. 5162.
Upon the completion of communication parameter setting, set the
parameter below. When the parameter below is set to 1, the CNC
acquires the communication parameters, and initializes and opens the
port. Set the parameter to 0 once remote diagnosis ends.
- Bit 6 (RDN) of No. 0000 = 1
The optional reader/punch interface is not required.
3.3.2 Making a Connection Via the RS-232-C Interface:
Using an External Modem or Making a Direct Connection
For the Series 16i/18i/21i
Make the following parameter settings:
- Bit 0 (SB2) of No. 0201 = 0
- Bit 1 (ASC) of No. 0201 = 1
- Bit 2 (NCR) of No. 0201 = 1
- No. 0203 = 1 to 12
(For details, see Appendix B.)