B-65332EN/01 SAFETY PRECAUTIONS
1.2 WARNING
WARNING
- Be safely dressed when handling a motor.
Wear safety shoes or gloves when handling a motor as you may get
urt on any edge or protrusion on it or electric shocks. h
- Any person having a medical apparatus must keep at least 30 cm away from any
rotor.
A rotor contains very strong magnets. If a person has a medical
apparatus and does not keep a safe distance, the medical apparatus
may malfunction. Any person having a medical apparatus such as a
pacemaker or defibrillation equipment must not handle the motor if
ossible to prevent any accidents. p
- Do not unpack any rotor from the packing box until starting work.
A rotor contains very strong magnets. Do not unpack any rotor from
he packing box until starting work to prevent any accidents. t
- Do not remove the tin plates and corrugated cardboard for protection unless it is
necessary.
Corrugated cardboard and tin plates are attached to a rotor (using
magnetic force) to protect the rotor and reduce magnetic leakage. Do
not remove the tin plates and corrugated cardboard for protection also
uring work unless it is necessary. d
- When moving a rotor, place it flat with the mounting side facing up and slide it.
When moving a rotor on a table after unpacking it, always place it flat
with the mounting side facing up and slide it. If the table is made of
magnetic materials, rotating the rotor on its magnet surface, it is
highly dangerous. This is because your hand may be caught between
he rotor and table. t
- Use tapped holes for moving a motor only.
If another part is installed on the motor or the motor is installed on a
machine, in particular, never use the tapped holes. Tapped holes
hould be used only for lifting the motor and installing the motor. s
- When moving the motor, use a crane or another equipment.
A motor is a heavy object. Use a crane or another equipment as
equired (for the weight of the motor, see this manual). r
- Be careful of the magnetic attraction when installing the motor.
A synchronous built-in servo motor has the magnet attraction about
2N/cm
2
. Before work, consider the magnetic attraction, prepare
evices, and take safety measures to prevent accidents. d
s-3